Skip navigation

putin IS MURDERER

Please use this identifier to cite or link to this item: https://oldena.lpnu.ua/handle/ntb/42609
Full metadata record
DC FieldValueLanguage
dc.contributor.authorПістун, Євген
dc.contributor.authorКріль, Богдан
dc.contributor.authorРоманюк, Олександр
dc.contributor.authorКріль, Олександр
dc.contributor.authorPistun, Yevhen
dc.contributor.authorKril, Bohdan
dc.contributor.authorRomaniuk, Oleksandr
dc.contributor.authorKril, Oleksandr
dc.date.accessioned2018-09-05T13:56:52Z-
dc.date.available2018-09-05T13:56:52Z-
dc.date.created2017-11-10
dc.date.issued2017-11-10
dc.identifier.citationInvestigation of sensor for measurement of rotation angle of sensitive element in rotational paper pulp consistometer / Yevhen Pistun, Bohdan Kril, Oleksandr Romaniuk, Oleksandr Kril // Energy Engineering and Control Systems. — Lviv : Lviv Politechnic Publishing House, 2017. — Vol 3. — No 2. — P. 73–80.
dc.identifier.urihttps://ena.lpnu.ua/handle/ntb/42609-
dc.description.abstractРозглянуто результати теоретичного та експериментального дослідження оптичного давача для вимірювання кута повороту чутливого елемента ротаційного концентратоміра паперової пульпи. Стверджено, що для ротаційних концентратомірів має застосовуватись спеціалізований пристрій з двох дисків максимально можливого діаметра з прорізами по колу, а для зменшення середньоквадратичного відхилення результатів окремих вимірювань доцільно застосувати ще одну оптопару для фіксації початку оброблення сигналу. Весь цикл вимірювання кута повороту чутливого елемента проводиться за фіксовану кількість повних обертів основного вала приладу. Результати дослідження можна використати під час розроблення ротаційних концентратомірів паперової пульпи за схемами з компенсацією моменту в’язкісного тертя та за схемами з прямим вимірюванням моменту в’язкісного тертя за кутом повороту чутливого елемента.
dc.description.abstractThis paper presents the results of theoretical and experimental testing of an optical rotation angle sensor of rotational paper pulp consistency meter. It is suggested that a specialized device consisting of two discs with the diameter as large as possible should be applied in the rotational consistency meters. There are holes in the disks. One more optocoupler should be applied for registering the beginning of the signal processing of separate measurements in order to reduce the root-mean square error. The measurement cycle of the sensitive element rotation angle is conducted within a predetermined number of full turns of the main shaft. The research results can be applied during development of the paper pulp rotation consistency meters based on the compensation of the viscous friction torque and based on the direct measurement of the viscous friction by defining the rotation angle of the sensitive element.
dc.format.extent73-80
dc.language.isoen
dc.publisherLviv Politechnic Publishing House
dc.relation.ispartofEnergy Engineering and Control Systems, 2 (3), 2017
dc.relation.urihttp://www.prorheo.de/fileadmin/user_upload/pdfs/Covimat_205_DD_zF.pdf
dc.relation.urihttp://www.brookfieldengineering.com/products/viscometers/in-line-processviscometers/
dc.relation.urihttps://www.btg.com/en/products/products-by-type/inline-instrumentation/consistency/consistency-detail/155/
dc.subjectвимірювання
dc.subjectконцентрація паперової пульпи
dc.subjectротаційний концентратомір
dc.subjectоптичний давач
dc.subjectмагнітоелектричний перетворювач
dc.subjectpaper pulp consistency
dc.subjectmeasurement
dc.subjectrotation consistency meter
dc.subjectoptical sensor
dc.subjectmagneto-electric transducer
dc.titleInvestigation of sensor for measurement of rotation angle of sensitive element in rotational paper pulp consistometer
dc.title.alternativeДослідження давача для вимірювання кута повороту чутливого елемента ротаційного концентратоміра паперової пульпи
dc.typeArticle
dc.rights.holder© 2017 The Authors. Published by Lviv Polytechnic National University
dc.contributor.affiliationНаціональний університет “Львівська політехніка”
dc.contributor.affiliationLviv Polytechnic National University
dc.format.pages8
dc.identifier.citationenInvestigation of sensor for measurement of rotation angle of sensitive element in rotational paper pulp consistometer / Yevhen Pistun, Bohdan Kril, Oleksandr Romaniuk, Oleksandr Kril // Energy Engineering and Control Systems. — Lviv : Lviv Politechnic Publishing House, 2017. — Vol 3. — No 2. — P. 73–80.
dc.relation.references[1] Michael H. Waller (1993) A tutorial on the measurement of paper stock consistency. ISA Transactions 32, 277–282.
dc.relation.references[2] Steffe J.F. (1996) Rheological Methods in Food process Engineering. Second edition. Freeman press, East Lansing, MI, USA 418p.
dc.relation.references[3] Covimat 205. URL: http://www.prorheo.de/fileadmin/user_upload/pdfs/Covimat_205_DD_zF.pdf
dc.relation.references[4] TT-100 Viscometer e for In-line System Applications. URL: http://www.brookfieldengineering.com/products/viscometers/in-line-processviscometers/ tt-100-viscometer
dc.relation.references[5] Ekhard Preikschat (1997) Rotating consistency transmitter impeller and method. US Patent No. 5684247.
dc.relation.references[6] JT-Tieto Oy & Marjo Nygård (2010) Metso Rotating Consistency Transmitter. Installation & Owner's Manual K09157 V1.0 EN Metso Automation Inc. Documentation. www.metso.com/automation
dc.relation.references[7] MEK-2300 with JCT-1100 User manual (2002) BTG Pulp and Paper Technology AB, Säffle, Sweden.
dc.relation.references[8] Andersson N., Kullander J., Lundberg P., Adrian P. (2012) Phase Controller for a Dual Motor Torque Detecting Device. US Patent No.: US8171776 B2.
dc.relation.references[9] MEK-3000 TwinTorque URL:https://www.btg.com/en/products/products-by-type/inline-instrumentation/consistency/consistency-detail/155/
dc.relation.referencesen[1] Michael H. Waller (1993) A tutorial on the measurement of paper stock consistency. ISA Transactions 32, 277–282.
dc.relation.referencesen[2] Steffe J.F. (1996) Rheological Methods in Food process Engineering. Second edition. Freeman press, East Lansing, MI, USA 418p.
dc.relation.referencesen[3] Covimat 205. URL: http://www.prorheo.de/fileadmin/user_upload/pdfs/Covimat_205_DD_zF.pdf
dc.relation.referencesen[4] TT-100 Viscometer e for In-line System Applications. URL: http://www.brookfieldengineering.com/products/viscometers/in-line-processviscometers/ tt-100-viscometer
dc.relation.referencesen[5] Ekhard Preikschat (1997) Rotating consistency transmitter impeller and method. US Patent No. 5684247.
dc.relation.referencesen[6] JT-Tieto Oy & Marjo Nygård (2010) Metso Rotating Consistency Transmitter. Installation & Owner's Manual K09157 V1.0 EN Metso Automation Inc. Documentation. www.metso.com/automation
dc.relation.referencesen[7] MEK-2300 with JCT-1100 User manual (2002) BTG Pulp and Paper Technology AB, Säffle, Sweden.
dc.relation.referencesen[8] Andersson N., Kullander J., Lundberg P., Adrian P. (2012) Phase Controller for a Dual Motor Torque Detecting Device. US Patent No., US8171776 B2.
dc.relation.referencesen[9] MEK-3000 TwinTorque URL:https://www.btg.com/en/products/products-by-type/inline-instrumentation/consistency/consistency-detail/155/
dc.citation.volume3
dc.citation.issue2
dc.citation.spage73
dc.citation.epage80
dc.coverage.placenameLviv
Appears in Collections:Energy Engineering And Control Systems. – 2017. – Vol. 3, No. 2

Files in This Item:
File Description SizeFormat 
2017v3n2_Pistun_Y-Investigation_of_sensor_for_73-80.pdf556.69 kBAdobe PDFView/Open
2017v3n2_Pistun_Y-Investigation_of_sensor_for_73-80__COVER.png432.2 kBimage/pngView/Open
Show simple item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.