Title: Load Bearing Capacity and Cracking Resistance to off-center Compression of Hollow Concrete Blocks
Other Titles: Несуча здатність і тріщиностійкість позацентрово стиснутих бетонних порожнистих блоків
Authors: Мельник, І.
Білозір, В.
Біденко, І.
Шуляр, Р.
Партута, В.
Melnyk, Ihor
Bilozir, Vitalii
Bidenko, Ivanna
Shulyar, Rostyslav
Partuta, Volodymyr
Affiliation: Національний університет “Львівська політехніка”
Львівський національний аграрний університет
Lviv Polytechnic National University
Lviv National Agrarian University
Bibliographic description (Ukraine): Load Bearing Capacity and Cracking Resistance to off-center Compression of Hollow Concrete Blocks / Ihor Melnyk, Vitalii Bilozir, Ivanna Bidenko, Rostyslav Shulyar, Volodymyr Partuta // Theory and Building Practice. — Lviv : Lviv Politechnic Publishing House, 2020. — Vol 2. — No 2. — P. 119–126.
Bibliographic description (International): Load Bearing Capacity and Cracking Resistance to off-center Compression of Hollow Concrete Blocks / Ihor Melnyk, Vitalii Bilozir, Ivanna Bidenko, Rostyslav Shulyar, Volodymyr Partuta // Theory and Building Practice. — Lviv : Lviv Politechnic Publishing House, 2020. — Vol 2. — No 2. — P. 119–126.
Is part of: Theory and Building Practice, 2 (2), 2020
Issue: 2
Issue Date: 23-Mar-2020
Publisher: Видавництво Львівської політехніки
Lviv Politechnic Publishing House
Place of the edition/event: Львів
Lviv
DOI: doi.org/10.23939/jtbp2020.02.119
Keywords: фундаментні порожнисті блоки
несуча здатність
експериментальні дослідження
деформаційний метод
діаграми деформування
hollow foundation blocks
load bearing capacity
experimental research
deformation method
deformation diagram
Number of pages: 8
Page range: 119-126
Start page: 119
End page: 126
Abstract: Дослідження стосуються бетонних порожнистих блоків стін підвалів, які широко використовували і використовують в практиці будівництва. Показано, що навіть для середньоповерхових і багатоповерхових будівель міцність бетонних блоків використовуються лише на 10–30 %. Тому масивні фундаментні блоки доцільно виготовляти порожнистими. За конструкцією оптимізовані блоки можна об’єднати в такі групи: з крупними порожнинами, відкритими знизу, з вертикальними закритими і наскрізними порожнинами, горизонтальними порожнинами і ребристі. Розроблені конструкції ефективних блоків стін підвалів потенційно дають можливість значно облегшити їх і зекономити бетон. Проте майже всі запропоновані рішення не знайшли широкого використання на практиці – в основному внаслідок технологічних проблем. Необхідно продовжити пошук ефективних конструктивно- технологічних рішень блоків стін підвалів, та їх дослідження. У статті відображено результати експериментально-теоретичних досліджень фундаментних блоків двох типів: з двома відкритими зверху порожнинами марки ФБП-1 та з 4-ма закритими порожнинами марки ФБП-2. В блоці ФБП-2 порожнини улаштовані з використанням арболітових вставок. Така конструкція блоків є доцільною для зовнішніх стін підвалів, оскільки покращує теплотехнічні характеристики стіни. Випробовували блоки у складі 3-х ярусної стінки загальною висотою 1,8 м на позацентрово прикладене навантаження. Натурні випробування блоків дозволили отримати їхні фактичні значення міцності і тріщиностійкості. Розрахункова несуча здатність і тріщиностійкість блоків визначали за деформаційною методикою згідно з чинними нормативними документами з врахуванням і ідеалізованої діаграми деформування бетону за розтягу. Розрахунок за розробленою методикою натурних порожнистих блоків показав задовільну збіжність з експериментальними даними за показниками несучої здатності і тріщиностійкості
The research is about concrete hollow blocks that have been and still are used widely in basement wall construction. It shows that only 10–30 % of their strength is used even for mid and high-rise construction. Therefore massive foundation blocks should be made with hollows. By design, optimized blocks can be combined into the following groups: with large cavities, open from below, with vertical closed and through cavities, horizontal cavities and ribbed. The developed designs of effective blocks of walls of basements potentially give the chance to facilitate them considerably and to save concrete. However, almost of the proposed solutions have not been widely used in practice - mainly due to technological problems. It is necessary to continue the search for effective structural and technological solutions of basement wall blocks and their research. The article shows the result of experimental and theoretic research of two types of concrete blocks: FBH-1 with two top opened hollows and FBH-2 with 4 enclosed hollows. FBH-2 block has hollows with arbolite insertions. His type is efficient for basement external wall due superior thermal performance. The blocks were texted as a part of 3-storey masonry of 1.8 m height applying off-centric loads to it. Those texts allowed to get its actual strength capacity as well as cracking resistance. The load bearing capacity and cracking resistance have been calculated using a deformation method according to current codes. The method takes into account an idealized diagram of concrete stretching.The calculations according to developed method showed satisfactory matching with experimental data of load bearing capacity and cracking resistance.
URI: https://ena.lpnu.ua/handle/ntb/56581
Copyright owner: © Національний університет “Львівська політехніка”, 2020
© Melnyk I., Bilozir V., Bidenko I., Shulyar R., Partuta V., 2020
References (Ukraine): Malinina L. A., Folomeev A. A. (1985). Energy intensity of heavy concrete for precast and monolithic structures.
Overview, 49. Moscow (in Russian Federation).
Reinforced concrete and ecology. Concrete and reinforced concrete. (1993). (Vol. 3, pp. 30–31).
Malyugin V. I. (1958). Efficiency of precast concrete in construction. Moscow (in Russian Federation).
Efficient zero cycle constructs for high-rise buildings. Concrete and reinforced concrete. (1975). (Vol. 8,
pp. 38–40).
Report on NIR “Experimental study of hollow-core block panels of basement walls for residential and public
buildings”. Lviv Polytechnic Institute. (1989).
Shmukler V. S., Molodchenko G. A., Burak N. P., Lugchenko E. I. (2007). Concrete blocks with rational parameters.
Scientific Bulletin of Construction. (Vol. 42).
Akramul K. (1994). Study of the stress state and optimization of the parameters of concrete blocks with
complex geometry. Abstract. Dissertation for the degree of candidate of technical sciences, 18. Poltava (in Ukraine).
Luhchenko O. I. (2009). Rational hollow concrete and reinforced concrete structures: abstract of the dissertation
for the degree of Candidate of Technical Sciences: specialty 05.23.01, 22. Kharkiv (in Ukraine).
Tetior A. N. (1991). Effective foundation designs, 276. Kiev: UMK VO (in Ukraine).
Bau-Innovation Gesellschaftmobil & Co. KG. ISOPLUS-EXTRA. (1991). 2.
Melnyk I. V. Method of manufacturing hollow concrete and reinforced concrete products Declaratory patent
for invention. State Department of Intellectual Property. (Bull. No. 7-II from 15.12.2000 y).
Melnyk I. V., Pankiv M. I. (1999). Effective basemant wall blocks. Resource-saving materials, structures, buildings
and structures, 212–217. Rivne (in Ukraine).
Melnyk I. V. (2009). Strength of hollow foundation concrete blocks at different test shemes. Resource-saving materials, structures, buildings and structures.
(Vol. 19, pp. 198–2006).
Bambura A. M. (2006). Experimental bases of applied deformation theory of reinforced concrete: abstract of
the dissertation for the degree of Doctor of Technical Sciences: specialty. 05.23.01, 39. Kharkiv: KhDTUB (in Ukraine).
References (International): Malinina L. A., Folomeev A. A. (1985). Energy intensity of heavy concrete for precast and monolithic structures.
Overview, 49. Moscow (in Russian Federation).
Reinforced concrete and ecology. Concrete and reinforced concrete. (1993). (Vol. 3, pp. 30–31).
Malyugin V. I. (1958). Efficiency of precast concrete in construction. Moscow (in Russian Federation).
Efficient zero cycle constructs for high-rise buildings. Concrete and reinforced concrete. (1975). (Vol. 8,
pp. 38–40).
Report on NIR "Experimental study of hollow-core block panels of basement walls for residential and public
buildings". Lviv Polytechnic Institute. (1989).
Shmukler V. S., Molodchenko G. A., Burak N. P., Lugchenko E. I. (2007). Concrete blocks with rational parameters.
Scientific Bulletin of Construction. (Vol. 42).
Akramul K. (1994). Study of the stress state and optimization of the parameters of concrete blocks with
complex geometry. Abstract. Dissertation for the degree of candidate of technical sciences, 18. Poltava (in Ukraine).
Luhchenko O. I. (2009). Rational hollow concrete and reinforced concrete structures: abstract of the dissertation
for the degree of Candidate of Technical Sciences: specialty 05.23.01, 22. Kharkiv (in Ukraine).
Tetior A. N. (1991). Effective foundation designs, 276. Kiev: UMK VO (in Ukraine).
Bau-Innovation Gesellschaftmobil & Co. KG. ISOPLUS-EXTRA. (1991). 2.
Melnyk I. V. Method of manufacturing hollow concrete and reinforced concrete products Declaratory patent
for invention. State Department of Intellectual Property. (Bull. No. 7-II from 15.12.2000 y).
Melnyk I. V., Pankiv M. I. (1999). Effective basemant wall blocks. Resource-saving materials, structures, buildings
and structures, 212–217. Rivne (in Ukraine).
Melnyk I. V. (2009). Strength of hollow foundation concrete blocks at different test shemes. Resource-saving materials, structures, buildings and structures.
(Vol. 19, pp. 198–2006).
Bambura A. M. (2006). Experimental bases of applied deformation theory of reinforced concrete: abstract of
the dissertation for the degree of Doctor of Technical Sciences: specialty. 05.23.01, 39. Kharkiv: KhDTUB (in Ukraine).
Content type: Article
Appears in Collections:Theory and Building Practice. – 2020. – Vol. 2, No. 2

Files in This Item:
File Description SizeFormat 
2020v2n2_Melnyk_I-Load_Bearing_Capacity_and_119-126.pdf545.91 kBAdobe PDFView/Open
2020v2n2_Melnyk_I-Load_Bearing_Capacity_and_119-126__COVER.png386.02 kBimage/pngView/Open
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.