Skip navigation

putin IS MURDERER

Please use this identifier to cite or link to this item: https://oldena.lpnu.ua/handle/ntb/55662
Full metadata record
DC FieldValueLanguage
dc.contributor.authorЛабай, В. Й.
dc.contributor.authorЯрослав, В. Ю.
dc.contributor.authorДовбуш, О. М.
dc.contributor.authorЦізда, А.
dc.contributor.authorLabay, Volodymyr
dc.contributor.authorYaroslav, Vitaliy
dc.contributor.authorDovbush, Oleksandr
dc.contributor.authorTsizda, Andriy
dc.date.accessioned2020-12-13T12:37:21Z-
dc.date.available2020-12-13T12:37:21Z-
dc.date.created2020-02-10
dc.date.issued2020-02-10
dc.identifier.citationInfluence of the condenser and evaporator air flows on the condensation and evaporation pressures of air split-conditioners heat pumps / Volodymyr Labay, Vitaliy Yaroslav, Oleksandr Dovbush, Andriy Tsizda // Theory and Building Practice. — Lviv : Lviv Politechnic Publishing House, 2020. — Vol 2. — No 1. — P. 23–29.
dc.identifier.urihttps://ena.lpnu.ua/handle/ntb/55662-
dc.description.abstractВ умовах зростаючого дефіциту та росту цін на паливно-енергетичні ресурси проблема енергозбереження та використання альтернативних джерел енергії для вирішення проблеми зменшення енергоспоживання для економіки України стає дуже важливою. Сьогодні стає все розповсюдженішим використання теплових помп split-кондиціонерів у системах теплопостачання будівель. Тому вдосконалення конструкції і роботи енергетичного обладнання, до якого належать теплові помпи split-кондиціонерів (“повітря-повітря”), пов’язане з детальним вивченням їх роботи та об’єктивною оцінкою ступеня їх енергетичної досконалості, що може бути визначена лише на основі аналізу їх ексергетичної ефективності. Це дозволило обґрунтувати актуальність такого дослідницького завдання, що пов’язано з недостатньою інформацією щодо режимів роботи, пов’язаних із впливом потоків повітря на конденсаторі і випарнику на відповідні тиски конденсації і випаровування, та ексергетичної ефективності використання теплових помп split-кондиціонерів. Для цієї статті використано авторську інноваційну математичну модель для аналізу роботи одноступеневих фреонових теплових помп, які використовуються у split-кондиціонерах, за ексергетичним методом. Встановлено залежність тисків конденсації і випаровування та ексергетичного ККД на прикладі теплової помпи split-кондиціонера фірми “Mitsubishi Electric” з номінальною теплопродуктивністю 3067 Вт за стандартних зовнішніх температурних умов на холодильному агенті R32 від потоків повітря на конденсаторі і випарнику.
dc.description.abstractIn the face of growing shortages and rising prices for fuel and energy resources, the problem of energy conservation and the use of alternative energy sources to solve the problem of reducing energy consumption for the Ukrainian economy become very important. Today, the use of air splitconditioner heat pumps in buildings' heating systems is becoming more common. Therefore, the improvement of the design and operation of power equipment to which air split-conditioner heat pumps (“air-air”) are related is related to a detailed study of their operation and an objective assessment of their degree of energy perfection, which can only be determined on the basis of analysis their exergy efficiency. This made it possible to substantiate the relevance of such a research task due to the insufficient information on the operating modes related to the influence of air flows on the condenser and evaporator on the corresponding condensation and evaporation pressures and the exergetic efficiency of the use of air split-conditioners. For this article it was used the author's innovation mathematical model to analysis of the operation of one-step freon heat pumps, which are used in air split-conditioners, according to the exergetic method. The dependence of condensation and evaporation pressures and exergetic output-input ratio (OIR) on the example of “Mitsubishi Electric” firm air split-conditioner heat pump with the nominal heating capacity of 3067 W under the standard external temperature conditions on the refrigerant R32 was determined from the condenser and evaporator air flows.
dc.format.extent23-29
dc.language.isoen
dc.publisherВидавництво Львівської політехніки
dc.publisherLviv Politechnic Publishing House
dc.relation.ispartofTheory and Building Practice, 1 (2), 2020
dc.relation.urihttp://www.ukrenergo.energy.gov.ua
dc.subjectтеплова помпа
dc.subjectsplit-кондиціонер
dc.subjectтиски конденсації і випаровування
dc.subjectпотоки повітря на конденсаторі і випарнику
dc.subjectексергетична ефективність
dc.subjectheat pump
dc.subjectair split-conditioner
dc.subjectcondensation and evaporation pressures
dc.subjectcondenser and evaporator air flows
dc.subjectexergetic efficiency
dc.titleInfluence of the condenser and evaporator air flows on the condensation and evaporation pressures of air split-conditioners heat pumps
dc.title.alternativeВплив повітряних потоків на конденсаторі і випарнику на тиски конденсації і випаровування теплових помп split-кондиціонерів
dc.typeArticle
dc.rights.holder© Національний університет “Львівська політехніка”, 2020
dc.rights.holder© Labay V., Yaroslav V., Dovbush O., Tsizda A., 2020
dc.contributor.affiliationНаціональний університет “Львівська політехніка”
dc.contributor.affiliationLviv Polytechnic National University
dc.format.pages7
dc.identifier.citationenInfluence of the condenser and evaporator air flows on the condensation and evaporation pressures of air split-conditioners heat pumps / Volodymyr Labay, Vitaliy Yaroslav, Oleksandr Dovbush, Andriy Tsizda // Theory and Building Practice. — Lviv : Lviv Politechnic Publishing House, 2020. — Vol 2. — No 1. — P. 23–29.
dc.identifier.doidoi.org/10.23939/jtbp2020.01.023
dc.relation.referencesEnergy Strategy of Ukraine until 2030 (2013) [Electronic resource]. – Access mode: – http://www.ukrenergo.energy.gov.ua (in Ukrainian).
dc.relation.referencesBezrodniy M. N., Dranik T. V. (2013) Thermodynamic efficiency of heat pump application for providing
dc.relation.referencescomfortable conditions in indoor pools. Eastern European Journal of Enterprise Technologies 3 (8), 25–30 (in Ukrainian).
dc.relation.referencesZalewski P. K. (2001) Pompy ciepła. Podstawy teoretyczne i przykłady zastosowania. I.P.P.U. MASTA Sp. z o.o., Krakόw (іn Polish).
dc.relation.referencesShargut E., Petela R. (1968) Exergy. Moscow: Energy (in Russian).
dc.relation.referencesSokolov E. Ya., Brodiansky V. M. (1981) Energy bases of heat transformation and cooling processes.
dc.relation.referencesMoscow: Energoizdat (in Russian).
dc.relation.referencesSilvio de Oliveira Junior. (2013) Exergy. Production, Cost and Renewability. Springer (in English).
dc.relation.referencesBejan A. (1988) Advanced Engineering Thermodynamics. New York: J. Wiley (in English).
dc.relation.referencesBejan A., Tsatsaronis G., Moran M. (1996) Thermal Design and Optimization. New York: J. Wiley (in English).
dc.relation.referencesMorosuk T., Nikulshin R., Morosuk L. (2006) Entropy-Cycle Method for Analysis of Refrigeration Machine
dc.relation.referencesand Heat Pump Cycles. THERMAL SCIENCE 10 (1), 111–124 (in English).
dc.relation.referencesMorozyuk T. V. (2006) The theory of refrigeration machines and heat pumps. Odessa: Studio “Negotsiant”
dc.relation.references(in Russian).
dc.relation.referencesTsatsaronis J. (2002) The interaction of thermodynamics and economics to minimize the cost of an energy
dc.relation.referencesconversion system. Odessa: Studio “Negotsiant” (in Russian).
dc.relation.referencesLabay V., Dovbush O., Yaroslav V. and Klymenko H. (2018) Mathematical Modeling of a Split-conditioner
dc.relation.referencesOperation for Evaluation of Exergy Efficiency of the R600A Refrigerant Application. Scientific Journal
dc.relation.references“Mathematical Modeling and Computing” (Математичне моделювання та інформаційні технології) 5 (2), 169–177 (in English).
dc.relation.referencesLabay V. Yo., Khanyk Ya. M. (2008) Energy Saving Ratio Between the Air Flows at the Evaporator and
dc.relation.referencesCondenser Air Split-conditioners. Scientific and Technical Journal “Refrigeration Engineering and Technology” 6 (116), 28–31 (in Ukrainian).
dc.relation.referencesJakobsen A., Rassmussen B.-D., Skovrup M.-J., Andersen S.-E. (2001) CoolPack – a collection of simulation
dc.relation.referencestools for refrigeration – Tutorial – Version 1.46. – Department of Energy Engineering Technical University of
dc.relation.referencesDenmark (in English).
dc.relation.referencesMitsubishi Electric Catalogo Split (2019) (in English).
dc.relation.referencesenEnergy Strategy of Ukraine until 2030 (2013) [Electronic resource], Access mode: – http://www.ukrenergo.energy.gov.ua (in Ukrainian).
dc.relation.referencesenBezrodniy M. N., Dranik T. V. (2013) Thermodynamic efficiency of heat pump application for providing
dc.relation.referencesencomfortable conditions in indoor pools. Eastern European Journal of Enterprise Technologies 3 (8), 25–30 (in Ukrainian).
dc.relation.referencesenZalewski P. K. (2001) Pompy ciepła. Podstawy teoretyczne i przykłady zastosowania. I.P.P.U. MASTA Sp. z o.o., Krakόw (in Polish).
dc.relation.referencesenShargut E., Petela R. (1968) Exergy. Moscow: Energy (in Russian).
dc.relation.referencesenSokolov E. Ya., Brodiansky V. M. (1981) Energy bases of heat transformation and cooling processes.
dc.relation.referencesenMoscow: Energoizdat (in Russian).
dc.relation.referencesenSilvio de Oliveira Junior. (2013) Exergy. Production, Cost and Renewability. Springer (in English).
dc.relation.referencesenBejan A. (1988) Advanced Engineering Thermodynamics. New York: J. Wiley (in English).
dc.relation.referencesenBejan A., Tsatsaronis G., Moran M. (1996) Thermal Design and Optimization. New York: J. Wiley (in English).
dc.relation.referencesenMorosuk T., Nikulshin R., Morosuk L. (2006) Entropy-Cycle Method for Analysis of Refrigeration Machine
dc.relation.referencesenand Heat Pump Cycles. THERMAL SCIENCE 10 (1), 111–124 (in English).
dc.relation.referencesenMorozyuk T. V. (2006) The theory of refrigeration machines and heat pumps. Odessa: Studio "Negotsiant"
dc.relation.referencesen(in Russian).
dc.relation.referencesenTsatsaronis J. (2002) The interaction of thermodynamics and economics to minimize the cost of an energy
dc.relation.referencesenconversion system. Odessa: Studio "Negotsiant" (in Russian).
dc.relation.referencesenLabay V., Dovbush O., Yaroslav V. and Klymenko H. (2018) Mathematical Modeling of a Split-conditioner
dc.relation.referencesenOperation for Evaluation of Exergy Efficiency of the R600A Refrigerant Application. Scientific Journal
dc.relation.referencesen"Mathematical Modeling and Computing" (Matematychne modeliuvannia ta informatsiini tekhnolohii) 5 (2), 169–177 (in English).
dc.relation.referencesenLabay V. Yo., Khanyk Ya. M. (2008) Energy Saving Ratio Between the Air Flows at the Evaporator and
dc.relation.referencesenCondenser Air Split-conditioners. Scientific and Technical Journal "Refrigeration Engineering and Technology" 6 (116), 28–31 (in Ukrainian).
dc.relation.referencesenJakobsen A., Rassmussen B.-D., Skovrup M.-J., Andersen S.-E. (2001) CoolPack – a collection of simulation
dc.relation.referencesentools for refrigeration – Tutorial – Version 1.46, Department of Energy Engineering Technical University of
dc.relation.referencesenDenmark (in English).
dc.relation.referencesenMitsubishi Electric Catalogo Split (2019) (in English).
dc.citation.issue1
dc.citation.spage23
dc.citation.epage29
dc.coverage.placenameЛьвів
dc.coverage.placenameLviv
Appears in Collections:Theory and Building Practice. – 2020. – Vol. 2, No. 1

Files in This Item:
File Description SizeFormat 
2020v2n1_Labay_V-Influence_of_the_condenser_23-29.pdf412.65 kBAdobe PDFView/Open
2020v2n1_Labay_V-Influence_of_the_condenser_23-29__COVER.png443.32 kBimage/pngView/Open
Show simple item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.