Title: Computer-Aided Design of Gas Flow Temperature Measurement Errors
Authors: Dychuk, Petro
Fedoryshyn, Roman
Affiliation: Lviv Polytechnic National University
Bibliographic description (Ukraine): Dychuk P. Computer-Aided Design of Gas Flow Temperature Measurement Errors / Petro Dychuk, Roman Fedoryshyn // Litteris et Artibus : proceedings, 23–25 November 2018, Lviv. — Lviv : Lviv Politechnic Publishing House, 2018. — P. 135–137. — (8th International academic conference “Electric power engineering & control systems 2018” (EPECS-2018)).
Bibliographic description (International): Dychuk P. Computer-Aided Design of Gas Flow Temperature Measurement Errors / Petro Dychuk, Roman Fedoryshyn // Litteris et Artibus : proceedings, 23–25 November 2018, Lviv. — Lviv : Lviv Politechnic Publishing House, 2018. — P. 135–137. — (8th International academic conference “Electric power engineering & control systems 2018” (EPECS-2018)).
Is part of: Litteris et Artibus : proceedings, 2018
Conference/Event: 8th International youth science forum «Litteris et Artibus»
Journal/Collection: Litteris et Artibus : proceedings
Issue Date: 22-Nov-2018
Publisher: Видавництво Львівської політехніки
Lviv Politechnic Publishing House
Place of the edition/event: Львів
Lviv
Temporal Coverage: 23–25 November 2018, Lviv
Keywords: gas
errors
computer-aided design
measurement of gas temperature
temperature transducers
Number of pages: 3
Page range: 135-137
Start page: 135
End page: 137
Abstract: The system for computer-aided calculation of additional systematic errors of natural gas temperature measurement is developed. Calculation is made for the data on real working conditions of the gas metering unit. The following errors are calculated by the system: error caused by heat exchange between the thermometer case and the pipe wall, error caused by heat exchange between the pipe wall and the ambient air, error caused by temperature decrease as the gas is throttled through the pressure differential device.
URI: https://ena.lpnu.ua/handle/ntb/51735
ISBN: 978-966-941-294-2
Copyright owner: © Національний університет “Львівська політехніка”, 2018
References (Ukraine): [1] Y. Pistun and L. Lesovoi. “Normalization of pressure differential flowmeters” Publishing House of Institute of Energy Audit and Energy Carrier Accounting (www.ieoe.com.ua), Lviv, p. 576, 2006, ISBN 966-553-541-2
[2] Y. Pistun. “Metering and saving of natural gas”, Oil and gas industry. vol. 2. – pp. 43–47. 2000.
[3] F. Matiko and R. Fedoryshyn. “Investigation of influence of natural gas flow temperature regime on the accuracy of flowrate measurement by means of differential pressure method”, Lviv, Proceedings of Lviv Polytechnic National University "Automation, measurement and control.", No. 574, pp. 29-38, 2007.
References (International): [1] Y. Pistun and L. Lesovoi. "Normalization of pressure differential flowmeters" Publishing House of Institute of Energy Audit and Energy Carrier Accounting (www.ieoe.com.ua), Lviv, p. 576, 2006, ISBN 966-553-541-2
[2] Y. Pistun. "Metering and saving of natural gas", Oil and gas industry. vol. 2, pp. 43–47. 2000.
[3] F. Matiko and R. Fedoryshyn. "Investigation of influence of natural gas flow temperature regime on the accuracy of flowrate measurement by means of differential pressure method", Lviv, Proceedings of Lviv Polytechnic National University "Automation, measurement and control.", No. 574, pp. 29-38, 2007.
Content type: Conference Abstract
Appears in Collections:Litteris et Artibus. – 2018 р.

Files in This Item:
File Description SizeFormat 
2018_Dychuk_P-Computer_Aided_Design_of_135-137.pdf215.97 kBAdobe PDFView/Open
2018_Dychuk_P-Computer_Aided_Design_of_135-137__COVER.png418.73 kBimage/pngView/Open
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.