https://oldena.lpnu.ua/handle/ntb/46468
Title: | Quantitative Determination of Ephedrine Hydrochloride in Pharmaceutical Injections by Highly Sensitive Turbidimetric and Reversed-Phase Combined with UFLC Methods |
Other Titles: | Кількісне визначення гідрохлориду ефедріну у фармацевтичних ін‘екціях високочутливим турбидиметричним методом і обернено-фазною надшвидкою рідинною хроматографією |
Authors: | Jeber, Jalal N. |
Affiliation: | Universities of Baghdad |
Bibliographic description (Ukraine): | Jeber J. N. Quantitative Determination of Ephedrine Hydrochloride in Pharmaceutical Injections by Highly Sensitive Turbidimetric and Reversed-Phase Combined with UFLC Methods / Jalal N. Jeber // Chemistry & Chemical Technology. — Lviv : Lviv Politechnic Publishing House, 2019. — Vol 13. — No 2. — P. 269–274. |
Bibliographic description (International): | Jeber J. N. Quantitative Determination of Ephedrine Hydrochloride in Pharmaceutical Injections by Highly Sensitive Turbidimetric and Reversed-Phase Combined with UFLC Methods / Jalal N. Jeber // Chemistry & Chemical Technology. — Lviv : Lviv Politechnic Publishing House, 2019. — Vol 13. — No 2. — P. 269–274. |
Is part of: | Chemistry & Chemical Technology, 2 (13), 2019 |
Issue: | 2 |
Issue Date: | 28-Feb-2019 |
Publisher: | Видавництво Львівської політехніки Lviv Politechnic Publishing House |
Place of the edition/event: | Львів Lviv |
Keywords: | обернено-фазна надшвидка рідинна хроматографія гідрохлорид ефедрину турбидиметрія фармацевтичні препарати UFLC ephedrine hydrochloride turbidity pharmaceutical preparations |
Number of pages: | 6 |
Page range: | 269-274 |
Start page: | 269 |
End page: | 274 |
Abstract: | За допомогою турбидиметричного методу
та обернено-фазної надшвидкої рідинної хроматографії (НРХ)
визначено кількість гідрохлориду ефедрину у фармацевтичних
ін‘єкціях. Першим методом на основі турбидиметричних
величин утвореного жовтувато-білого осаду у вигляді суспензії
визначено концентрацію гідрохлориду ефедрину. Суспензія утво-
рюється внаслідок реакції між гідрохлоридом ефедрину та
флуоромолібденовою кислотою, яку використовували як реа-
гент. Досліджено її фізико-хімічні характеристики та побудо-
вано калібрувальні графіки ефедрину. У другому способі (НРХ)
використано рухому фазу метанол-вода (55:45, об. %; рН
води 3,5). Кількість гідрохлориду ефедрину визначали з вико-
ристанням УФ-детектора при 260 нм. Лінійність ефедрину
встановлено в діапазоні 0,09–0,39 ммоль·л-1, а межа чутливості
для турбидиметричного та НРХ методу становила 0,4 та
0,0044 ммоль·л-1, відповідно. Показано, що розроблені методи
можна успішно застосовувати для кількісного визначення гідро-
хлориду ефедрину в лабораторних препаратах (стандарт) та ко-
мерційних фармацевтичних ін‘єкціях. Відносні стандартні від-
хилення обох методів знаходяться в інтервалі 0,65–1,69%, що
вказує на коректну відтворюваність і високу точність методів. In this paper, turbidimetric and reversed-phase ultra-fast liquid chromatography (UFLC) methods were described for the quantitative determination of ephedrine hydrochloride in pharmaceutical injections form. The first method is based on measuring the turbidimetric values for the formed yellowish white precipitate in suspension status in order to determine the ephedrine hydrochloride concentration. The suspended substance is formed as a result of the reaction of ephedrine hydrochloride with phosphomolybdic acid which was used as a reagent. The physical and chemical characteristics of the complex were investigated. The calibration graphs of ephedrine were established by turbidity method. While the second method (UFLC) was conducted using the methanol-water (55+45, v/v) as the mobile phase with adjusted water pH 3.5. The ephedrine hydrochloride was detected and measured using UV detector at 260 nm. The linearity of ephedrine was obtained in the range of 0.09–0.39 mmol·l-1. The detection limits (LOD) for the ephedrine hydrochloride were found to be 0.4 and 0.0044 mmol·l-1 by turbidity and UFLC, respectively. The developed methods were successfully applied for the quantitative determination of ephedrine hydrochloride in laboratory preparations (standard) and in commercial pharmaceutical injections. The two methods have given relative standard deviations (R.S.D.) in the range of 0.65–1.69 %, which indicates reasonable repeatability and high precision of both methods. |
URI: | https://ena.lpnu.ua/handle/ntb/46468 |
Copyright owner: | © Національний університет „Львівська політехніка“, 2019 © Jeber J., 2019 |
URL for reference material: | https://doi.org/10.1016/0021-9673(92)85575-E https://doi.org/10.1007/s11655-014-1952-x https://doi.org/10.1007/978-3-319-32328-2_11 https://doi.org/10.1002/ptr.1337 https://doi.org/10.1016/S0731-7085(02)00065-1 https://doi.org/10.1016/j.saa.2013.03.038 https://doi.org/10.5740/jaoacint.17-0078 https://doi.org/10.1007/BF00322242 https://doi.org/10.1002/dta.1963 https://doi.org/10.1016/S1570-0232(03)00222-8 https://doi.org/10.1080/10826076.2017.1287723 https://doi.org/10.1007/s10337-016-3170-5 https://doi.org/10.1016/S0731-7085(99)00103-X https://doi.org/10.1248/yakushi1947.120.6_583 https://doi.org/10.1016/S0379-0738(03)00101-4 https://doi.org/10.1016/S1570-0232(02)00522-6 https://doi.org/10.1093/chromsci/bmw082 https://doi.org/10.1016/j.chroma.2011.09.078 https://doi.org/10.1016/j.jchromb.2017.10.062 https://doi.org/10.1016/j.forsciint.2017.06.026 https://doi.org/10.1016/j.snb.2016.05.058 https://doi.org/10.1016/j.talanta.2012.10.067 https://doi.org/10.1016/j.jchromb.2015.12.027 https://doi.org/10.1080/10826076.2017.1300171 https://doi.org/10.1016/j.jchromb.2016.11.039 https://doi.org/10.1093/chromsci/bmw165 https://doi.org/10.1002/dta.1803 |
References (Ukraine): | 1. Pharmacopoeia of the People’s Republic of China, v.1. 1990. 2. Liu Y.M., Sheu S.J.: J. Chromatogr. A, 1992, 600, 370. https://doi.org/10.1016/0021-9673(92)85575-E 3. Mei F., Xing X., Tang Q. et al.: Chinese J. Integrat. Medicine, 2016, 22, 445. https://doi.org/10.1007/s11655-014-1952-x 4. Wagner H., Bauer R., Melchart D., Staudinger A.: Herba Ephedrae – Mahuang. [in:]Wagner H., Bauer R., Melchart D., Staudinger A. (Eds.), Chromatographic Fingerprint Analysis of Herbal Medicines, v. IV. Springer, Cham, 2016, 107-114. https://doi.org/10.1007/978-3-319-32328-2_11 5. Abourashed E., El‐Alfy A., Khan I., Walker L.: Phytother. Res., 2003, 17, 703. https://doi.org/10.1002/ptr.1337 6. Pharmacopoeia B., A96, 1972. 7. Şentürk Z., Erk N., Özkan S. et al.: J. Pharm. Biomed., 2002, 29, 291. https://doi.org/10.1016/S0731-7085(02)00065-1 8. Abdel-Ghani N., RizkM., MostafaM.: Spectrochim. Acta A, 2013, 111, 131. https://doi.org/10.1016/j.saa.2013.03.038 9. Moustafa A., HegazyM., Mohamed D., Ali O.: J. AOAC Int., 2018, 101, 414. https://doi.org/10.5740/jaoacint.17-0078 10. Parimoo P., Umapathi P., Srinivasan K.: Indian Drugs, 1992, 29, 442. 11. Pascual-Marti M., Marin Saez R., Iranzo Adrian J.: Fresen. J. Anal. Chem., 1995, 352, 396. https://doi.org/10.1007/BF00322242 12. Miao L., Liu Y., Li H. et al.: Drug Test. Analys., 2017, 9, 221. https://doi.org/10.1002/dta.1963 13. Mateus-Avois L., Mangin P., SaugyM.: J. Chromatogr. B, 2003, 791, 203. https://doi.org/10.1016/S1570-0232(03)00222-8 14. An Q., Dong Y., Lu N., Li N.: J. Liq. Chromatogr. R. T., 2017, 40, 177. https://doi.org/10.1080/10826076.2017.1287723 15. Tircova B., Kozlik P.: Chromatographia, 2017, 80, 523. https://doi.org/10.1007/s10337-016-3170-5 16. Boberić-Borojević D., Radulović D., Ivanović D., Ristić P.: J. Pharm. Biomed., 1999, 21, 15. https://doi.org/10.1016/S0731-7085(99)00103-X 17. NakanoM., Morimoto Y., Tajima S. et al.: J. Pharm. Soc. Japan, 2000, 120, 583. https://doi.org/10.1248/yakushi1947.120.6_583 18. El-Haj B., Al-Amri A., HassanM. et al.: Forensic Sci. Int., 2003, 135, 16. https://doi.org/10.1016/S0379-0738(03)00101-4 19. Gentili S., Torresi A., Marsili R. et al.: J. Chromatogr. B, 2002, 780, 183. https://doi.org/10.1016/S1570-0232(02)00522-6 20. Mohamed K., Al-Hazmi A., Alasiri A., Ali M.: J. Chromatogr. Sci., 2016, 54, 1271. https://doi.org/10.1093/chromsci/bmw082 21. Fotouhi L., Yamini Y., Molaei S., Seidi S.: J. Chromatogr. A, 2011, 1218, 8581. https://doi.org/10.1016/j.chroma.2011.09.078 22. Baharfar M., Yamini Y., Seidi S., Karami M.: J. Chromatogr. B, 2017, 1068, 313. https://doi.org/10.1016/j.jchromb.2017.10.062 23. Hanna G.: J. AOAC Int., 1995, 78, 946. 24. Bogun B., Moore S.: Forensic Sci. Int., 2017, 278, 68. https://doi.org/10.1016/j.forsciint.2017.06.026 25. Shawish H., ElhabibyM., Aziz H. et al.: Sensor. Actuat. BChem., 2016, 235, 18. https://doi.org/10.1016/j.snb.2016.05.058 26. Hassan S., Kamel A., El-Naby H.: Talanta, 2013, 103, 330. https://doi.org/10.1016/j.talanta.2012.10.067 27. Wang J.-W., ChiangM.-H., Lu C.-M., Tsai T.-H.: J. Chromatogr. B, 2016, 1026, 152. https://doi.org/10.1016/j.jchromb.2015.12.027 28. Baharfar M., Yamini Y., Seidi S., Karami M.: J. Chromatogr. B, 2017, 1068, 313. https://doi.org/10.1016/j.jchromb.2017.10.062 29. Rouhani G., Ertekin Z., Dinç E.: J. Liq. Chromatogr. R. T., 2017, 40, 333. https://doi.org/10.1080/10826076.2017.1300171 30. Taghvimi A., Hamishehkar H.: J. Chromatogr. B, 2017, 1041, 113. https://doi.org/10.1016/j.jchromb.2016.11.039 31. Xu J., Yan R.: J. Chromatogr. Sci., 2017, 55, 162. https://doi.org/10.1093/chromsci/bmw165 32. Kojima A., Nishitani Y., SatoM. et al.: Drug Test. Analysis, 2016, 8, 189. https://doi.org/10.1002/dta.1803 |
References (International): | 1. Pharmacopoeia of the People’s Republic of China, v.1. 1990. 2. Liu Y.M., Sheu S.J., J. Chromatogr. A, 1992, 600, 370. https://doi.org/10.1016/0021-9673(92)85575-E 3. Mei F., Xing X., Tang Q. et al., Chinese J. Integrat. Medicine, 2016, 22, 445. https://doi.org/10.1007/s11655-014-1952-x 4. Wagner H., Bauer R., Melchart D., Staudinger A., Herba Ephedrae – Mahuang. [in:]Wagner H., Bauer R., Melchart D., Staudinger A. (Eds.), Chromatographic Fingerprint Analysis of Herbal Medicines, v. IV. Springer, Cham, 2016, 107-114. https://doi.org/10.1007/978-3-319-32328-2_11 5. Abourashed E., El‐Alfy A., Khan I., Walker L., Phytother. Res., 2003, 17, 703. https://doi.org/10.1002/ptr.1337 6. Pharmacopoeia B., A96, 1972. 7. Şentürk Z., Erk N., Özkan S. et al., J. Pharm. Biomed., 2002, 29, 291. https://doi.org/10.1016/S0731-7085(02)00065-1 8. Abdel-Ghani N., RizkM., MostafaM., Spectrochim. Acta A, 2013, 111, 131. https://doi.org/10.1016/j.saa.2013.03.038 9. Moustafa A., HegazyM., Mohamed D., Ali O., J. AOAC Int., 2018, 101, 414. https://doi.org/10.5740/jaoacint.17-0078 10. Parimoo P., Umapathi P., Srinivasan K., Indian Drugs, 1992, 29, 442. 11. Pascual-Marti M., Marin Saez R., Iranzo Adrian J., Fresen. J. Anal. Chem., 1995, 352, 396. https://doi.org/10.1007/BF00322242 12. Miao L., Liu Y., Li H. et al., Drug Test. Analys., 2017, 9, 221. https://doi.org/10.1002/dta.1963 13. Mateus-Avois L., Mangin P., SaugyM., J. Chromatogr. B, 2003, 791, 203. https://doi.org/10.1016/S1570-0232(03)00222-8 14. An Q., Dong Y., Lu N., Li N., J. Liq. Chromatogr. R. T., 2017, 40, 177. https://doi.org/10.1080/10826076.2017.1287723 15. Tircova B., Kozlik P., Chromatographia, 2017, 80, 523. https://doi.org/10.1007/s10337-016-3170-5 16. Boberić-Borojević D., Radulović D., Ivanović D., Ristić P., J. Pharm. Biomed., 1999, 21, 15. https://doi.org/10.1016/S0731-7085(99)00103-X 17. NakanoM., Morimoto Y., Tajima S. et al., J. Pharm. Soc. Japan, 2000, 120, 583. https://doi.org/10.1248/yakushi1947.120.6_583 18. El-Haj B., Al-Amri A., HassanM. et al., Forensic Sci. Int., 2003, 135, 16. https://doi.org/10.1016/S0379-0738(03)00101-4 19. Gentili S., Torresi A., Marsili R. et al., J. Chromatogr. B, 2002, 780, 183. https://doi.org/10.1016/S1570-0232(02)00522-6 20. Mohamed K., Al-Hazmi A., Alasiri A., Ali M., J. Chromatogr. Sci., 2016, 54, 1271. https://doi.org/10.1093/chromsci/bmw082 21. Fotouhi L., Yamini Y., Molaei S., Seidi S., J. Chromatogr. A, 2011, 1218, 8581. https://doi.org/10.1016/j.chroma.2011.09.078 22. Baharfar M., Yamini Y., Seidi S., Karami M., J. Chromatogr. B, 2017, 1068, 313. https://doi.org/10.1016/j.jchromb.2017.10.062 23. Hanna G., J. AOAC Int., 1995, 78, 946. 24. Bogun B., Moore S., Forensic Sci. Int., 2017, 278, 68. https://doi.org/10.1016/j.forsciint.2017.06.026 25. Shawish H., ElhabibyM., Aziz H. et al., Sensor. Actuat. BChem., 2016, 235, 18. https://doi.org/10.1016/j.snb.2016.05.058 26. Hassan S., Kamel A., El-Naby H., Talanta, 2013, 103, 330. https://doi.org/10.1016/j.talanta.2012.10.067 27. Wang J.-W., ChiangM.-H., Lu C.-M., Tsai T.-H., J. Chromatogr. B, 2016, 1026, 152. https://doi.org/10.1016/j.jchromb.2015.12.027 28. Baharfar M., Yamini Y., Seidi S., Karami M., J. Chromatogr. B, 2017, 1068, 313. https://doi.org/10.1016/j.jchromb.2017.10.062 29. Rouhani G., Ertekin Z., Dinç E., J. Liq. Chromatogr. R. T., 2017, 40, 333. https://doi.org/10.1080/10826076.2017.1300171 30. Taghvimi A., Hamishehkar H., J. Chromatogr. B, 2017, 1041, 113. https://doi.org/10.1016/j.jchromb.2016.11.039 31. Xu J., Yan R., J. Chromatogr. Sci., 2017, 55, 162. https://doi.org/10.1093/chromsci/bmw165 32. Kojima A., Nishitani Y., SatoM. et al., Drug Test. Analysis, 2016, 8, 189. https://doi.org/10.1002/dta.1803 |
Content type: | Article |
Appears in Collections: | Chemistry & Chemical Technology. – 2019. – Vol. 13, No. 2 |
File | Description | Size | Format | |
---|---|---|---|---|
2019v13n2_Jeber_J_N-Quantitative_Determination_269-274.pdf | 237.52 kB | Adobe PDF | View/Open | |
2019v13n2_Jeber_J_N-Quantitative_Determination_269-274__COVER.png | 509.68 kB | image/png | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.