Skip navigation

putin IS MURDERER

Please use this identifier to cite or link to this item: https://oldena.lpnu.ua/handle/ntb/40524
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBinkevych, Taras
dc.coverage.temporal23–25 листопада 2017 року
dc.coverage.temporal23–25 November, 2017
dc.date.accessioned2018-04-12T13:07:04Z-
dc.date.available2018-04-12T13:07:04Z-
dc.date.created2017-12-23
dc.date.issued2017-12-23
dc.identifier.citationBinkevych T. Means and devices of lightning protection of overhead transmission lines of voltage class 110–750 kV / Taras Binkevych // Litteris et Artibus : proceedings, 23–25 November, 2017. — Lviv : Lviv Polytechnic Publishing House, 2017. — P. 166–167. — (7th International academic conference «Electric power engineering & control systems 2017» (EPECS-2017)).
dc.identifier.isbn978-966-941-108-2
dc.identifier.urihttps://ena.lpnu.ua/handle/ntb/40524-
dc.description.abstractTraditionally, the overhead transmission line (OTL) can not function normally without special lightning protection. The article considers the main means and devices of lightning protection of OTL 110-750 kV according to the current normative documentation. The peculiarities of use and consequences of the establishment of certain protection means are indicated. A series of mathematical simulations was carried out, resulting in the level of overvoltages using the means and devices of lightning protection and their absence.
dc.format.extent166-167
dc.language.isoen
dc.publisherВидавництво Львівської політехніки
dc.publisherLviv Polytechnic Publishing House
dc.relation.ispartofLitteris et Artibus : матеріали, 2017
dc.relation.ispartofLitteris et Artibus : proceedings, 2017
dc.subjectlightning protection
dc.subjectthe overhead transmission line
dc.subjectovervoltages
dc.subjectreliability of lightning protection
dc.subjectcoordination of isolation
dc.titleMeans and devices of lightning protection of overhead transmission lines of voltage class 110–750 kV
dc.typeConference Abstract
dc.rights.holder© Національний університет “Львівська політехніка”, 2017
dc.contributor.affiliationLviv Polytechnic National University
dc.format.pages2
dc.identifier.citationenBinkevych T. Means and devices of lightning protection of overhead transmission lines of voltage class 110–750 kV / Taras Binkevych // Litteris et Artibus : proceedings, 23–25 November, 2017. — Lviv : Lviv Polytechnic Publishing House, 2017. — P. 166–167. — (7th International academic conference «Electric power engineering & control systems 2017» (EPECS-2017)).
dc.relation.references[1] Pravyla ulashtuvannja elektroustanovok . vyd.3 , pererob. i dop. Minpalyvenergo Ukrai'ny, Kyi'v ,2010.
dc.relation.references[2] Zhurahivs'kyj A.V., Impul'snyj opir zazemlennja opor povitrjanyh linij ta jogo vplyv na nadijnist' grozozahystu, A. V. Zhurahivs'kyj, I. V. Lishhak, T. V. Binkevych, Visnyk Vinnyc'kogo politehnichnogo instytutu. № 1, pp. 74-78, 2016.
dc.relation.references[3] V. S. Sobchuk and O. B. Burykin, Perenaprugy i blyskavkozahyst v elektrychnyh systemah : navchal'nyj posibnyk,. Vinnycja : VNTU, 2010.
dc.relation.references[4] Vernon Cooray, «Lightning Protection», Published by The Institution of Engineering and Technology, London, United Kingdom, 2010
dc.relation.references[5] Ustrojstva molnyezashhyty y zazemlenyja tehnycheskyh sredstv,STO 08.026-2015
dc.relation.references[6] Rukovodstvo po zashhyte еlektrycheskyh setej 6-1150 kv ot grozovyh y vnutrennyh perenaprjazhenyj, Rossyjskoe akcyonernoe obshhestvo energetyky y elektryfykacyy «EES Rossyy»,1999 g.
dc.relation.referencesen[1] Pravyla ulashtuvannja elektroustanovok . vyd.3 , pererob. i dop. Minpalyvenergo Ukrai'ny, Kyi'v ,2010.
dc.relation.referencesen[2] Zhurahivs'kyj A.V., Impul'snyj opir zazemlennja opor povitrjanyh linij ta jogo vplyv na nadijnist' grozozahystu, A. V. Zhurahivs'kyj, I. V. Lishhak, T. V. Binkevych, Visnyk Vinnyc'kogo politehnichnogo instytutu. No 1, pp. 74-78, 2016.
dc.relation.referencesen[3] V. S. Sobchuk and O. B. Burykin, Perenaprugy i blyskavkozahyst v elektrychnyh systemah : navchal'nyj posibnyk,. Vinnycja : VNTU, 2010.
dc.relation.referencesen[4] Vernon Cooray, "Lightning Protection", Published by The Institution of Engineering and Technology, London, United Kingdom, 2010
dc.relation.referencesen[5] Ustrojstva molnyezashhyty y zazemlenyja tehnycheskyh sredstv,STO 08.026-2015
dc.relation.referencesen[6] Rukovodstvo po zashhyte elektrycheskyh setej 6-1150 kv ot grozovyh y vnutrennyh perenaprjazhenyj, Rossyjskoe akcyonernoe obshhestvo energetyky y elektryfykacyy "EES Rossyy",1999 g.
dc.citation.conference7th International youth science forum «Litteris et Artibus»
dc.citation.journalTitleLitteris et Artibus : матеріали
dc.citation.spage166
dc.citation.epage167
dc.coverage.placenameЛьвів
dc.coverage.placenameLviv
Appears in Collections:Litteris et Artibus. – 2017 р.

Files in This Item:
File Description SizeFormat 
2017_Binkevych_T-Means_and_devices_of_166-167.pdf122.52 kBAdobe PDFView/Open
2017_Binkevych_T-Means_and_devices_of_166-167__COVER.png1.61 MBimage/pngView/Open
Show simple item record