Skip navigation

putin IS MURDERER

Please use this identifier to cite or link to this item: https://oldena.lpnu.ua/handle/ntb/39966
Title: Research and analysis of rapidly changing gas flow temperatures measurement methods
Other Titles: Дослідження та аналіз методів вимірювання швидкозмінних температур газових потоків
Authors: Василь, Фединець
Леонід, Лесовой
Богдан, Чабан
Vasyl, Fedynets
Leonid, Lesovoi
Bohdan, Chaban
Affiliation: Національний університет “Львівська політехніка”
Lviv Polytechnic National University
Bibliographic description (Ukraine): Fedynets V. Research and analysis of rapidly changing gas flow temperatures measurement methods / Vasyl Fedynets, Leonid Lesovoi, Bohdan Chaban // Energy Engineering and Control Systems. — Lviv : Printing Center of lviv Politechnic Publishing House, 2017. — Vol 3. — No 1. — P. 29–36.
Is part of: Energy engineering and control systems, 1 (3), 2017
Issue: 1
Issue Date: 14-Feb-2017
Publisher: Printing Center of lviv Politechnic Publishing House
Place of the edition/event: Lviv
Keywords: газовий потік
вимірювання
теплообмін
температура
перетворювач температури
gas flow
measurement
heat exchange
temperature
temperature transducer
Number of pages: 8
Page range: 29-36
Start page: 29
End page: 36
Abstract: Внаслідок певного значення теплоємності чутливого елемента перетворювача температури його температура завжди відставатиме від температури газового потоку, якщо вона змінилася. Під час вимірювання змінної в часі температури потоку перетворювач також не встигає стежити за зміною температури, оскільки для зміни температури його чутливого елемента потрібен деякий час. Спотворення показів перетворювача через нестаціонарності теплових процесів як у самому перетворювачі, так і між перетворювачем і навколишнім середовищем зумовлені його тепловою інерцією. Оскільки повного уникнення інерційності реального перетворювача температур досягти неможливо, за практичних вимірювань температур газового потоку, що змінюються в часі, використовують перетворювачі, які мають деяке скінченне значення показника теплової інерції. За таких вимірювань отримувати потрібну інформацію можливо за допомогою аналізу запису самого нестаціонарного процесу вимірювання, здійснюючи прямий розрахунок температур середовища, або вносити поправку на запізнення в покази перетворювача температур. Досліджено та проаналізовано методи вимірювання швидкозмінних температур газових потоків шляхом їх прямого розрахунку та введенням поправки в покази перетворювачів температури.
The temperature of a transducer sensitive element, as a result of its heat capacity, will always lag behind the temperature of the gas flow if this temperature changes. When measuring the flow temperature that varies in time, the transducer doesn’t follow the changes in temperature immediately because its sensitive element temperature changes after some time. The distortions of the transducer readings are caused by the thermal inertia due to non-stationary heat processes in the transducers, as well as between transducer and the environment. Since complete elimination of real temperature transducer inertia is not possible, the transducers with some finite values of the thermal inertia are used at practice to measure the varying gas flow temperature. The necessary information about the flow temperature can be obtained by analyzing the record of the non-stationary measurement process. In this case a direct calculation of the flow temperature is made or a correction of the temperature transducer readings delay is made. The results of research and analysis of measurement methods of rapidly changing gas flow temperatures by the direct calculation of the flow temperature and by correcting the temperature transducer readings are presented in this paper.
URI: https://ena.lpnu.ua/handle/ntb/39966
ISSN: 2411-8028
Copyright owner: © Lviv Politecnic National University,2017
© 2017, The Authors. Published by Lviv Polytechnic National University
References (International): [1] Moffat, R. J. (1962). Gas Temperature Measurement. Temperature: Its Measurement and Control in Science and Industry, 3(2), 321.
[2] Vas, I. E. (1972). Flow Field Measurements Using Total Temperature Probe at Hypersonic Speeds. AIAA, 10(3), 317–323.
[3] Giedt, W. H., Chambers, J. T.-A. (1965). Dual-Element Transducer for Measuring High Gas-Stream Temperatures. Heat Transfer, 87(3), 397–402.
[4] Benson, R. S., Brundrett, G. W. (1966). Development of resistance wire thermometer for measurement of the transient temperatures in exhaust system of internal combustion engines. Measurement of transient temperature and heat flux. Reinhold Publ. Co., 56–91.
[5] Kilburg, H. P. (1968). A High Response Probe for Measurement of Total Temperature and Totalpressure Profiles through a Turbulent Boundary Layer with Heat Transfer in Supersonic Flow. AIAA, 9.
[6] Alverman, W. (1986). Determination of temperature profiles by means of thermocouples. Ztschr. fur Plugwissenschaften, 4, 179–183.
[7] Softley, E. J. (1968). Use of a Pulse Heated Fine Wire Probe for the Measurement of Total Temperature in Shock Driven Facilities. AIAA, 12.
[8] Quamby, A. (1984). Transcient Response of Wire Resistance Thermometers. RAS, 646, 696–698.
[9] Basic Theory of Millisecond Response Thermocouples (1970). Instrument Practice, 10, 687–691.
Content type: Article
Appears in Collections:Energy Engineering And Control Systems. – 2017. – Vol. 3, No. 1

Files in This Item:
File Description SizeFormat 
2017v3n1_Vasyl_F-Research_and_Analysis_of_Rapidly_29-36.pdf557.73 kBAdobe PDFView/Open
2017v3n1_Vasyl_F-Research_and_Analysis_of_Rapidly_29-36__COVER.png465.28 kBimage/pngView/Open
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.